Sensor designed for all BAXI heat pumps from the Auriga series
Sensor cable length: 8m
Sensor ends with a connector compatible with the socket located on the main board of the heat pump. Connecting the sensor only requires plugging it into the appropriate place on the main board.
The sensor is also compatible with sensors:
TIN (same as TW_in) - Measures water temperature at the inlet to the plate heat exchanger, i.e., water returning from the system.
TOUT (same as TW_out) - Measures water temperature at the outlet from the plate heat exchanger, i.e., water supplying the system.
T5 - Measures water temperature in the domestic hot water (DHW) tank.
T1 - Measures water temperature at the outlet of the auxiliary heater or other additional heat source.
T1B - Measures water temperature at the outlet for the second, separate heating zone (zone 2).
Leaks are a common problem for temperature sensors, resulting in damage from moisture. Our sensors provide water protection - the sensor is coated with high-temperature flexible silicone.
EAN: 6931240024089 SKU: 240869405
Water Flow Temperature Sensor Zone 2 Tw2 ( T1B ) and Sensor for solar system Tsolar.
Sensor designed for all BAXI heat pumps from the Auriga series
Sensor cable length: 8m
Sensor ends with a connector compatible with the socket located on the main board of the heat pump. Connecting the sensor only requires plugging it into the appropriate place on the main board.
The sensor is also compatible with sensors:
TIN (same as TW_in) - Measures water temperature at the inlet to the plate heat exchanger, i.e., water returning from the system.
TOUT (same as TW_out) - Measures water temperature at the outlet from the plate heat exchanger, i.e., water supplying the system.
T5 - Measures water temperature in the domestic hot water (DHW) tank.
T1 - Measures water temperature at the outlet of the auxiliary heater or other additional heat source.
T1B - Measures water temperature at the outlet for the second, separate heating zone (zone 2).
Leaks are a common problem for temperature sensors, resulting in damage from moisture. Our sensors provide water protection - the sensor is coated with high-temperature flexible silicone.
Sensor Parameters
Sensor compatible with BAXI Auriga series
Purpose: BAXI Heat Pumps
Sensor measuring range: from -40 to +400 °C
Ingress Protection: IP68
Or designations: TIN, TOUT, T5, T1, T1B
Sensor placed in a sleeve with a diameter: 6mm and length: 50mm, made of stainless steel
Cable Termination: Plastic connector matching the socket on the heat pump main board.
Cable length: 8m (315 inches)
Cable Parameters
Cable parameters:
Cable type: Control / signal cable
Operating voltage: 300/300V
Voltage test: ≤ 0.34mm2 1200 V , ≥ 0.5 mm2 1500 V
Insulation resistance: 20 MΩ x km
Capacitance: (at 800Hz): 0.14mm2 120pF/m, ≥0.25 mm2 150pF/m
Inductance: 0.65 mH/km
Min. bending radius for mobile connection: 7.5 x Ø
Min. bending radius for fixed installation: 4 x Ø
Operating temperature: Fixed installation: -40℃ to 80℃ , Mobile installations: -5℃ to 80℃
Laying conditions: Indoor cable, Min. laying temperature: -5℃
Environmental resistance: Flame retardant on a single cable
Certificates / Approvals: CPR - Certificates / DoP
Cable construction:
Conductor material: copper conductors
Conductor structure: Class 5 (acc. to EN 60228, IEC 60228)
Core construction: multi-core cable
Application: Cables intended for control and signaling circuits in industrial applications, in measurement technology, and for data transmission via analog and digital signals in industrial electronics and automation installations. For fixed installation and mobile devices. Suitable for indoor installations, in dry and damp rooms.
Other Information
Temperature sensors with different cable lengths are available in our offer
Set contents
Temperature sensor with 8m cable
Certificates and standards
CE, RoHS
Dimensions, Weight
Product dimensions: 50 x 200 x 200 mm (D x W x H)
Package dimensions: 100 x 200 x 50 mm (D x W x H)
Product weight: 270 g
Weight with packaging: 290 g