Temperature sensor:

Buffer tank - Tbt1 Tbt2 (Tbt1 - Top part of the buffer tank, Tbt2 - Bottom part of the buffer tank)

DHW domestic hot water tank - T5

2 zone sensor - Tw2

Solar systems - Tsolar

Designed for many split and monoblock heat pumps with a built-in tank:

Kaisai (series KHC KHA KMK)

MIDEA

Rotenso (series Aquami)

GALMET PRIMA

YORK (series YKF)

Hyundai

Netsu

Aiva

Nordis

Sensor cable length: 15m

The sensor comes with a 0.5m adapter finished with a connector matching the socket on the heat pump motherboard. Connecting the sensor requires only plugging the sensor into the adapter, and plugging the adapter into the appropriate place on the motherboard.

Lack of tightness is a common problem with temperature sensors, resulting in damage by moisture. Our sensors provide water protection - the sensor is coated with high-temperature flexible silicone.

Quantity
Product available

DHW Temperature Sensor T5 Buffer Tank Tbt1 Tbt2 Tsolar Tw2 Heat Pump Kaisai Rotenso MIDEA NORDIS 15m

Model: ACTii AC9415

EAN: 6931240094150 SKU: 941569558

  • High-quality precision temperature sensor
  • Uses a specialized copper flexible control cable BiT LiYY 2x0.5mm, voltage: 300/300V, operating temperature: -40℃ to 80℃ compliant with EU standard: LVD 2014/35/EU
  • Sensor placed in a sleeve with diameter: 6mm and length: 50mm, made of stainless steel
  • Each sensor is tested for 3 different temperatures to ensure measurement accuracy with the reference sensor.
  • Water protection - Sensor coated with high-temperature flexible silicone. Leaks are a common problem for temperature sensors, leading to damage from moisture.
  • Our temperature sensors are of higher quality. Unlike the competition, we use only 100% copper, thick certified control cable made in the EU with thick and flexible insulation. We use branded sensors. Each sensor is checked by us for measurement compliance with the reference sensor.
  • Sensor finished with a connector matching the socket on the heat pump motherboard. Connecting the sensor only requires plugging it into the appropriate place on the motherboard.

Description

Temperature sensor:

Buffer tank - Tbt1 Tbt2 (Tbt1 - Top part of the buffer tank, Tbt2 - Bottom part of the buffer tank)

DHW domestic hot water tank - T5

2 zone sensor - Tw2

Solar systems - Tsolar

Designed for many split and monoblock heat pumps with a built-in tank:

Kaisai (series KHC KHA KMK)

MIDEA

Rotenso (series Aquami)

GALMET PRIMA

YORK (series YKF)

Hyundai

Netsu

Aiva

Nordis

Sensor cable length: 15m

The sensor comes with a 0.5m adapter finished with a connector matching the socket on the heat pump motherboard. Connecting the sensor requires only plugging the sensor into the adapter, and plugging the adapter into the appropriate place on the motherboard.

Lack of tightness is a common problem with temperature sensors, resulting in damage by moisture. Our sensors provide water protection - the sensor is coated with high-temperature flexible silicone.

Specification

Sensor Parameters

Sensor measurement range: from -40 to +400 °C

Tightness: IP68

Sensor placed in a sleeve with diameter: 6mm and length: 50mm, made of stainless steel

Cable termination: Plastic connector matching the socket on the heat pump motherboard.

Part numbers: CGQ-WD/SWD3970-L10000-AMP2(RSG) , 11201007000223 , RASN-MTFEXT , RASN-MTF2A , RASN-MTF1A

Cable length: 15m (591 inches)

Adapter length: 0.5m (20 inches)

Cable Parameters

Cable parameters:

Cable type: Control / signal cable

Operating voltage: 300/300V

Voltage test: ≤ 0.34mm2 1200 V , ≥ 0.5 mm2 1500 V

Insulation resistance: 20 MΩ x km

Capacitance: (at 800Hz): 0.14mm2 120pF/m, ≥0.25 mm2 150pF/m

Inductance: 0.65 mH/km

Min. bending radius for mobile connection: 7.5 x Ø

Min. bending radius for fixed connection: 4 x Ø

Operating temperature: Fixed installation: -40℃ to 80℃ , Mobile installations: -5℃ to 80℃

Laying conditions: Indoor cable, Min. laying temperature: -5℃

Environmental resistance: Flame retardant on a single cable

Certificates / Approvals: CPR - Certificates / DoP

Cable construction:

Core material: copper cores

Core construction: Class 5 (acc. to EN 60228, IEC 60228)

Core assembly: multi-core cable

Application: Cables intended for control and signaling circuits in industrial applications, in measurement technology, and for data transmission via analog and digital signals in industrial electronics and automation installations. For fixed installation and for mobile devices. Suitable for indoor use, in dry and damp rooms.

Other Information

A 15m cable length temperature sensor is also available in our offer

Set contents

1x Temperature sensor with 15m cable

1x 0.5m adapter

Certificates and standards

CE, RoHS

Dimensions, Weight

Product dimensions: 50 x 50 x 250 mm (Depth x Width x Height)

Package dimensions: 50 x 250 x 50 mm (Depth x Width x Height)

Product weight: 479 g

Weight with packaging: 499 g