Sensor designed for all Rotenso Aquami series heat pumps
Sensor cable length: 5m
Sensor finished with a connector compatible with the socket located on the main board in the heat pump. Connecting the sensor only requires plugging the sensor into the appropriate place on the main board.
Lack of tightness is a common problem for temperature sensors, resulting in their damage due to moisture. Our sensors provide water protection - the sensor is coated with high-temperature flexible silicone.
EAN: 6931240011058 SKU: 110558055
Water Flow Temperature Sensor Zone 2 Tw2 and Sensor for solar system Tsolar.
Sensor designed for all Rotenso Aquami series heat pumps
Sensor cable length: 5m
Sensor finished with a connector compatible with the socket located on the main board in the heat pump. Connecting the sensor only requires plugging the sensor into the appropriate place on the main board.
Lack of tightness is a common problem for temperature sensors, resulting in their damage due to moisture. Our sensors provide water protection - the sensor is coated with high-temperature flexible silicone.
Sensor Parameters
Sensor compatible with Rotenso Aquami series
Application: Rotenso Heat Pumps
Sensor measuring range: from -40 to +400 °C
Tightness: IP68
Or part number: RASN-MTF2A
Sensor housed in a sleeve with a diameter: 6mm and length: 50mm, made of stainless steel
Cable termination: Plastic connector compatible with the socket on the heat pump main board.
Cable length: 5m (196 inches)
Cable Parameters
Cable parameters:
Cable type: Control / signal cable
Operating voltage: 300/300V
Voltage test: ≤ 0.34mm2 1200 V , ≥ 0.5 mm2 1500 V
Insulation resistance: 20 MΩ x km
Capacitance: (at 800Hz): 0.14mm2 120pF/m, ≥0.25 mm2 150pF/m
Inductance: 0.65 mH/km
Min. bending radius flexible connection: 7.5 x Ø
Min. bending radius fixed connection: 4 x Ø
Operating temperature: Fixed installation: -40℃ to 80℃ , Flexible installations: -5℃ to 80℃
Laying conditions: Indoor cable, Min. laying temperature: -5℃
Environmental resistance: Flame retardant on a single cable
Certificates / Approvals: CPR - Certificates / DoP
Cable construction:
Conductor material: Copper conductors
Conductor construction: Cl.5 (according to EN 60228, IEC 60228)
Core structure: multi-core cable
Application: Cables intended for control and signaling circuits in industrial applications, measurement technology, and for data transmission via analog and digital signals in industrial electronics and automation installations. For fixed installations and moving devices. Suitable for indoor use, in dry and damp rooms.
Other Information
Temperature sensors with different cable lengths are available in our offer
Set contents
Temperature sensor with 5m long cable
Certificates and standards
CE, RoHS
Dimensions, Weight
Product dimensions: 50 x 200 x 200 mm (Depth x Width x Height)
Packaging dimensions: 100 x 200 x 50 mm (Depth x Width x Height)
Product weight: 250 g
Weight with packaging: 260 g
Specific References