• New
Single-phase RCBO Type AC 30mA 16A B-curve DIN fuse 1P+N 6kA module EATON HNB-B16/1N/003
search
  • Single-phase RCBO Type AC 30mA 16A B-curve DIN fuse 1P+N 6kA module EATON HNB-B16/1N/003
  • Single-phase RCBO Type AC 30mA 16A B-curve DIN fuse 1P+N 6kA module EATON HNB-B16/1N/003
  • Single-phase RCBO Type AC 30mA 16A B-curve DIN fuse 1P+N 6kA module EATON HNB-B16/1N/003
  • Single-phase RCBO Type AC 30mA 16A B-curve DIN fuse 1P+N 6kA module EATON HNB-B16/1N/003
  • Single-phase RCBO Type AC 30mA 16A B-curve DIN fuse 1P+N 6kA module EATON HNB-B16/1N/003

Single-phase RCBO Type AC 30mA 16A B-curve DIN fuse 1P+N 6kA module EATON HNB-B16/1N/003

zł230.39
Tax included
The HNB-B16/1N/003 RCBO is an advanced protective device that combines the functionality of a residual current circuit breaker and an overcurrent circuit breaker. It is an ideal solution for modern electrical installations where ensuring maximum user safety and property protection against electrical faults is crucial. Thanks to its Type B characteristic, this breaker is perfect for circuits powering lighting and standard sockets, protecting them against overloads and short circuits up to 6000 A. This device is the foundation of a safe residential and industrial installation.

One of the most important advantages of this model is its compact design. The device occupies only two modules in the distribution board (35.5 mm), which allows for significant space savings compared to using two separate devices. A rated residual current of 30 mA guarantees effective shock protection, reacting instantly to leakage current, which prevents dangerous consequences of electric shock. The breaker is designed for easy installation – screw terminals allow for secure connection of wires with a cross-section of up to 25 mm², and the special design enables the use of comb or pin busbars, which reduces installation time and minimizes the risk of assembly errors.

The Eaton brand product is distinguished by high reliability and durability, confirmed by numerous certificates and compliance with international standards. It is equipped with a clear, mechanical contact position indicator that informs about the device's operating status even in the absence of mains voltage. The ability to seal the lever protects against unauthorized interference with installation settings, which is particularly important in multi-family buildings and public utility facilities. The HNB-B16/1N/003 breaker is a guarantee of stable electrical system operation and peace of mind for residents and building administrators. A robust plastic housing resistant to high temperatures ensures safety of use for many years. It is an essential element of every professionally executed electrical distribution board, meeting rigorous safety standards and ensuring power continuity while protecting against hazards.

Quantity
Product available

Single-phase RCBO Type AC 30mA 16A B-curve DIN fuse 1P+N 6kA module

Model: EATON HNB-B16/1N/003

EAN: 6931240028209 SKU: 931028204

  • Combined Residual Current Circuit Breaker with Overcurrent Protection (RCBO)
  • Type B tripping characteristic for lighting and socket circuits
  • Rated residual current of 30 mA for shock protection
  • Rated current of 16 A for standard residential applications
  • High short-circuit breaking capacity of 6000 A (6 kA)
  • Mounting on standard TS-35 mm DIN rail
  • Mechanical contact position indicator (red/green)
  • Sealable lever for installation security
  • Compatibility with comb and pin busbars
  • Robust housing made of high-quality plastic

Description

The HNB-B16/1N/003 RCBO is an advanced protective device that combines the functionality of a residual current circuit breaker and an overcurrent circuit breaker. It is an ideal solution for modern electrical installations where ensuring maximum user safety and property protection against electrical faults is crucial. Thanks to its Type B characteristic, this breaker is perfect for circuits powering lighting and standard sockets, protecting them against overloads and short circuits up to 6000 A. This device is the foundation of a safe residential and industrial installation.

One of the most important advantages of this model is its compact design. The device occupies only two modules in the distribution board (35.5 mm), which allows for significant space savings compared to using two separate devices. A rated residual current of 30 mA guarantees effective shock protection, reacting instantly to leakage current, which prevents dangerous consequences of electric shock. The breaker is designed for easy installation – screw terminals allow for secure connection of wires with a cross-section of up to 25 mm², and the special design enables the use of comb or pin busbars, which reduces installation time and minimizes the risk of assembly errors.

The Eaton brand product is distinguished by high reliability and durability, confirmed by numerous certificates and compliance with international standards. It is equipped with a clear, mechanical contact position indicator that informs about the device's operating status even in the absence of mains voltage. The ability to seal the lever protects against unauthorized interference with installation settings, which is particularly important in multi-family buildings and public utility facilities. The HNB-B16/1N/003 breaker is a guarantee of stable electrical system operation and peace of mind for residents and building administrators. A robust plastic housing resistant to high temperatures ensures safety of use for many years. It is an essential element of every professionally executed electrical distribution board, meeting rigorous safety standards and ensuring power continuity while protecting against hazards.

Specification

Device type

Advanced Residual Current Circuit Breaker with Overcurrent Protection (RCBO) combining leakage current protection with overload and short-circuit protection. A device dedicated to single-phase networks, ensuring the highest level of safety for end users.

Tripping characteristic

Type B - instantaneous tripping at 3 to 5 times the rated current. Ideal for lighting circuits, general-purpose sockets, and low-inrush current equipment in residential construction.

Rated residual current

30 mA - threshold value ensuring effective shock protection against direct contact. Type AC reacts to sinusoidal residual currents, which is the standard in most domestic electrical installations.

Residual current tripping type

Type AC - designed to detect sinusoidal residual currents, providing optimal protection in standard AC circuits.

Rated current

16 A - maximum continuous current that can flow through the device without tripping the overcurrent element, matched to standard load circuits.

Number of poles

2 poles (1P+N) - design ensuring simultaneous disconnection of the phase and neutral paths, which increases safety during maintenance work.

Rated short-circuit breaking capacity

6000 A (6 kA) - maximum short-circuit current that the breaker can safely interrupt without damaging the device, ensuring installation safety in emergency situations.

Rated voltage

230 V AC / 50 Hz - standard operating parameters in European power grids, ensuring compatibility with most devices.

Terminal type

Robust screw (cage) terminals with high durability, allowing for secure wire fastening and minimization of contact resistance.

Wire cross-section

Supports a wide range of cross-sections from 1.5 mm² to 25 mm² (both solid and stranded wire), allowing for great flexibility during design and installation.

Contact position indicator

Integrated mechanical indicator (red/green colors) located on the front of the device, allowing for unambiguous identification of the main contact status regardless of the lever position.

Housing and mounting

Made of non-flammable plastic resistant to high temperatures, adapted for quick mounting on a standard TS-35 mm DIN rail.

Width in modules

The device width is 2 modules (35.5 mm), which allows for optimal use of space in electrical distribution boards and facilitates system modernization.

Selected features

Possibility of sealing in the ON and OFF positions, compatibility with comb and pin busbars, which significantly reduces installation time and improves wiring aesthetics.

Contents

1x HNB-B16/1N/003 RCBO

Dimensions, Weight

Product dimensions: 73 x 36 x 84 mm (D x W x H)

Package dimensions: 40 x 80 x 85 mm (D x W x H)

Product weight: 196 g

Package weight: 212 g

Zum Download

931028204
3 Items

Specific References

EAN13
6931240028209
Comments (0)
No customer reviews for the moment.