- New
The Eura GD-02A2 gas detector is an advanced safety device designed for continuous monitoring of explosive gases in enclosed spaces. The device is extremely versatile, as it can detect both natural gas (methane) and LPG (a mixture of propane and butane), making it an ideal solution for homes using gas installations, gas cylinders, or gas stoves.
The main advantage of the GD-02A2 model is its high efficiency and fast response time. Upon exceeding a safe gas concentration, which is just 10% of the lower explosive limit, the device immediately triggers a very loud acoustic alarm of over 85 dB and optical signaling in the form of a flashing LED. This noise level ensures that household members will be warned even during deep sleep, providing valuable time for evacuation and ventilation of the rooms.
Installation of the device is extremely simple and does not require specialized technical knowledge. Thanks to direct power supply from a 230V AC mains socket and a long power cord (1500 mm), the detector can be placed in an optimal location – near the ceiling for natural gas (which is lighter than air) or low near the floor for LPG (which is heavier). The solid housing and modern design ensure the device discreetly blends into any interior while providing the highest level of fire and explosion protection.
An additional advantage is the built-in test mode, which allows the user to check the correct operation of the sensor and siren at any time. The device also features a self-diagnostic system that informs about a potential sensor failure, which increases overall trust in the safety system. By choosing the Eura GD-02A2, you are investing in your and your family's peace of mind, minimizing the risk of tragic consequences from a gas leak.
EAN: 6931240032428 SKU: 931032422
The Eura GD-02A2 gas detector is an advanced safety device designed for continuous monitoring of explosive gases in enclosed spaces. The device is extremely versatile, as it can detect both natural gas (methane) and LPG (a mixture of propane and butane), making it an ideal solution for homes using gas installations, gas cylinders, or gas stoves.
The main advantage of the GD-02A2 model is its high efficiency and fast response time. Upon exceeding a safe gas concentration, which is just 10% of the lower explosive limit, the device immediately triggers a very loud acoustic alarm of over 85 dB and optical signaling in the form of a flashing LED. This noise level ensures that household members will be warned even during deep sleep, providing valuable time for evacuation and ventilation of the rooms.
Installation of the device is extremely simple and does not require specialized technical knowledge. Thanks to direct power supply from a 230V AC mains socket and a long power cord (1500 mm), the detector can be placed in an optimal location – near the ceiling for natural gas (which is lighter than air) or low near the floor for LPG (which is heavier). The solid housing and modern design ensure the device discreetly blends into any interior while providing the highest level of fire and explosion protection.
An additional advantage is the built-in test mode, which allows the user to check the correct operation of the sensor and siren at any time. The device also features a self-diagnostic system that informs about a potential sensor failure, which increases overall trust in the safety system. By choosing the Eura GD-02A2, you are investing in your and your family's peace of mind, minimizing the risk of tragic consequences from a gas leak.
Detection type
Natural gas (methane) and liquefied petroleum gas LPG (propane-butane). The device is calibrated to detect both types of combustible gases commonly used in households.
Sensor type
Advanced semiconductor sensor with high sensitivity and long service life, ensuring stable operation in domestic conditions.
Alarm threshold
Gas concentration less than or equal to 10% of the lower explosive limit (LEL). This allows for early warning before an explosive mixture is formed.
Acoustic signaling
Built-in piezoelectric siren generating a sound with a minimum intensity of 85 dB at a distance of 1 meter from the device.
Optical signaling
Red LED flashing in alarm mode and LEDs indicating power status and potential system failure.
Device power supply
Mains voltage 230 V AC, 50 Hz. The device does not require additional power adapters or batteries for primary operation.
Power consumption
Low power consumption during standby, allowing for continuous operation of the device without a significant impact on electricity bills.
Environmental conditions
Operating temperature in the range from -10 °C to +45 °C. Relative humidity permissible up to 95% (non-condensing).
Ingress protection class
IP20 - device intended for use inside dry rooms.
Cable length
Power cord with a length of 1500 mm terminated with a standard flat plug, facilitating installation in an optimal location.
Diagnostic functions
TEST button allowing verification of electronics and siren operation. Sensor health monitoring system with error signaling.
Software and logic
The built-in control algorithm analyzes signals from the semiconductor sensor in real-time. The firmware performs an automatic calibration function after power-up (sensor warm-up phase lasting approx. 180 seconds), which prevents false alarms. The system constantly monitors the continuity of the sensor circuit and, in case of detecting degradation of the measuring element or its damage, activates a yellow signaling LED and a short audible signal, informing the user about the need to replace the device.
Certificates and standards
Compliance with CE directives, declaration of conformity confirming compliance with European safety standards for domestic gas detectors.
Manufacturer warranty
24 months (2 years) from the date of purchase, carried out in the manufacturer's service system.
Contents
1x GD-02A2 gas detector with power cord
1x User manual in Polish
1x Set of mounting plugs
Dimensions, Weight
Product dimensions: 60 x 130 x 105 mm (D x W x H)
Packaging dimensions: 65 x 135 x 105 mm (D x W x H)
Product weight: 200 g
Weight with packaging: 204 g
Specific References