Water Flow Temperature Sensor Zone 2 Tw2 Tsolar Kaisai Heat Pump KHC KHA KMK 12m ACTii AC2112
search
  • Water Flow Temperature Sensor Zone 2 Tw2 Tsolar Kaisai Heat Pump KHC KHA KMK 12m ACTii AC2112
  • Water Flow Temperature Sensor Zone 2 Tw2 Tsolar Kaisai Heat Pump KHC KHA KMK 12m ACTii AC2112
  • Water Flow Temperature Sensor Zone 2 Tw2 Tsolar Kaisai Heat Pump KHC KHA KMK 12m ACTii AC2112

Water Flow Temperature Sensor Zone 2 Tw2 Tsolar Kaisai Heat Pump KHC KHA KMK 12m ACTii AC2112

zł123.41
Tax included Dostawa w ciągu 1-2 dni.
Water Flow Temperature Sensor Zone 2 Tw2 and Sensor for solar system Tsolar, designed for Kaisai heat pumps

Sensor designed for all Kaisai Heat pumps from the KHC KHA KMK series

Sensor cable length: 12m

Sensor finished with a connector that fits the socket on the mainboard in the heat pump. Connecting the sensor only requires plugging it into the appropriate place on the mainboard.

Lack of tightness is a common problem with temperature sensors, resulting in their damage due to moisture. Our sensors provide water protection - the sensor is coated with high-temperature flexible silicone.

Quantity
Produkt dostępny

Water Flow Temperature Sensor Zone 2 Tw2 Tsolar Kaisai Heat Pump KHC KHA KMK 12m

Model: ACTii AC2112

EAN: 6931240021125 SKU: 211286273

  • High-quality precision temperature sensor
  • Uses a specialized copper flexible control cable BiT LiYY 2x0.5mm, voltage: 300/300V, operating temperature: -40℃ to 80℃, compliant with EU standard: LVD 2014/35/EU
  • Sensor housed in a sleeve with a diameter: 6mm and length: 50mm, made of stainless steel
  • Each sensor is tested for 3 different temperatures to ensure measurement accuracy compared to a reference sensor.
  • Water protection - Sensor coated with high-temperature flexible silicone. Leaks are a common problem with temperature sensors, resulting in damage due to moisture.
  • Our temperature sensors are characterized by higher quality. Unlike the competition, we only use 100% thick copper certified control cable manufactured in the EU with thick and flexible insulation. We use sensors from branded companies. Each sensor is checked by us for measurement accuracy against a reference sensor.
  • Sensor finished with a connector that fits the socket on the mainboard in the heat pump. Connecting the sensor only requires plugging it into the appropriate place on the mainboard.

Description

Water Flow Temperature Sensor Zone 2 Tw2 and Sensor for solar system Tsolar, designed for Kaisai heat pumps

Sensor designed for all Kaisai Heat pumps from the KHC KHA KMK series

Sensor cable length: 12m

Sensor finished with a connector that fits the socket on the mainboard in the heat pump. Connecting the sensor only requires plugging it into the appropriate place on the mainboard.

Lack of tightness is a common problem with temperature sensors, resulting in their damage due to moisture. Our sensors provide water protection - the sensor is coated with high-temperature flexible silicone.

Specification

Sensor Parameters

Sensor compatible with Kaisai KHC KHA KMK series

Application: Kaisai Heat Pumps

Sensor measuring range: from -40 to +400 °C

Ingress protection: IP68

Sensor housed in a sleeve with a diameter: 6mm and length: 50mm, made of stainless steel

Cable termination: Plastic connector fitting the socket on the heat pump mainboard.

Cable length: 12m (472 inches)

Cable Parameters

Cable parameters:

Cable type: Control / signaling cable

Operating voltage: 300/300V

Voltage test: ≤ 0.34mm2 1200 V, ≥ 0.5 mm2 1500 V

Insulation resistance: 20 MΩ x km

Capacitance: (at 800Hz): 0.14mm2 120pF/m, ≥0.25 mm2 150pF/m

Inductance: 0.65 mH/km

Min. bending radius flexible connection: 7.5 x Ø

Min. bending radius fixed connection: 4 x Ø

Operating temperature: Fixed installation: -40℃ to 80℃, Flexible installations: -5℃ to 80℃

Laying conditions: Indoor cable, Min. laying temperature: -5℃

Environmental resistance: Flame retardant on a single cable

Certificates / Approvals: CPR - Certificates / DoP

Cable construction:

Conductor material: copper conductors

Conductor construction: Cl.5 (according to EN 60228, IEC 60228)

Core construction: multi-core cable

Application: Cables intended for control and signaling circuits in industrial applications, in measurement technology, and for data transmission via analog and digital signals in industrial electronics and automation installations. For fixed installation and for mobile devices. They are suitable for indoor use, in dry and damp rooms.

Other Information

Temperature sensors with different cable lengths are available in our offer

Set contents

Temperature sensor with a 12m long cable

Certificates and standards

CE, RoHS

Dimensions, Weight

Product dimensions: 50 x 50 x 250 mm (D x W x H)

Packaging dimensions: 50 x 250 x 50 mm (D x W x H)

Product weight: 370 g

Weight with packaging: 400 g