Temperature sensor Buffer tank temperature sensor Tbt1 Tbt2, designed for Kaisai heat pumps (Tbt1 - Upper part of the buffer tank, Tbt2 - Lower part of the buffer tank)

Sensor designed for all Kaisai heat pumps in the KHC KHA KMK series

Sensor cable length: 5m

Sensor finished with a connector compatible with the socket located on the motherboard in the heat pump. Connecting the sensor only requires plugging it into the appropriate spot on the motherboard.

Leaks are a common problem with temperature sensors, leading to damage from moisture. Our sensors provide water protection - the sensor is coated with high-temperature flexible silicone.

Quantity
Produkt dostępny

Buffer Tank Temperature Sensor Tbt1 Tbt2 for Kaisai Heat Pump KHC KHA KMK 5m

Model: ACTii AC1950

EAN: 6931240019504 SKU: 195086273

  • High-quality precision temperature sensor
  • Uses a specialized copper flexible control cable BiT LiYY 2x0.5mm, voltage: 300/300V, operating temperature: -40℃ to 80℃ compliant with EU standard: LVD 2014/35/EU
  • Sensor placed in a sleeve with a diameter of 6mm and a length of 50mm, made of stainless steel
  • Each sensor is tested for 3 different temperatures to ensure measurement accuracy compared to a reference sensor.
  • Water protection - Sensor coated with high-temperature flexible silicone. Leaks are a common problem with temperature sensors, leading to damage from moisture.
  • Our temperature sensors are characterized by higher quality. Unlike the competition, we use only 100% copper thick certified control cable produced in the EU in thick and flexible insulation. We use branded sensors. Each sensor is checked by us for measurement compliance with a reference sensor.
  • The sensor is finished with a connector compatible with the socket located on the motherboard in the heat pump. Connecting the sensor only requires plugging it into the appropriate spot on the motherboard.

Description

Temperature sensor Buffer tank temperature sensor Tbt1 Tbt2, designed for Kaisai heat pumps (Tbt1 - Upper part of the buffer tank, Tbt2 - Lower part of the buffer tank)

Sensor designed for all Kaisai heat pumps in the KHC KHA KMK series

Sensor cable length: 5m

Sensor finished with a connector compatible with the socket located on the motherboard in the heat pump. Connecting the sensor only requires plugging it into the appropriate spot on the motherboard.

Leaks are a common problem with temperature sensors, leading to damage from moisture. Our sensors provide water protection - the sensor is coated with high-temperature flexible silicone.

Specification

Sensor Parameters

Sensor compatible with Kaisai KHC KHA KMK series

Application: Kaisai Heat Pumps

Sensor measurement range: from -40 to +400 °C

Ingress protection: IP68

Sensor placed in a sleeve with a diameter: 6mm and length: 50mm, made of stainless steel

Cable termination: Plastic connector compatible with the socket on the heat pump motherboard.

Cable length: 5m (196 inches)

Cable Parameters

Cable parameters:

Cable type: Control / signal cable

Operating voltage: 300/300V

Voltage test: ≤ 0.34mm2 1200 V, ≥ 0.5 mm2 1500 V

Insulation resistance: 20 MΩ x km

Capacitance: (at 800Hz): 0.14mm2 120pF/m, ≥0.25 mm2 150pF/m

Inductance: 0.65 mH/km

Min. bending radius for mobile connection: 7.5 x Ø

Min. bending radius for fixed connection: 4 x Ø

Operating temperature: Fixed installation: -40℃ to 80℃, Mobile installations: -5℃ to 80℃

Laying conditions: Indoor cable, Min. laying temperature: -5℃

Environmental resistance: Flame retardant on a single cable

Certificates / Approvals / Authorizations: CPR - Certificates / DoP

Cable construction:

Conductor material: Copper conductors

Working conductor structure: Class 5 (acc. to EN 60228, IEC 60228)

Core structure: multi-core cable

Application: Cables intended for control and signaling circuits in industrial applications, measurement technology, and for data transmission via analog and digital signals in industrial electronics and automation installations. For fixed installation and mobile devices. Suitable for indoor installations, in dry and damp rooms.

Other Information

Temperature sensors with different cable lengths are available in our offer

Set contents

Temperature sensor with a 5m long cable

Certificates and standards

CE, RoHS

Dimensions, Weight

Product dimensions: 50 x 200 x 200 mm (D x W x H)

Package dimensions: 100 x 200 x 50 mm (D x W x H)

Product weight: 250 g

Weight with packaging: 260 g