EAN: 6931240099155 SKU: 991584652
In installations with long connections between the camera and the control station or installations located outside buildings, short-term surges induced in video or power cables often occur. They are caused by load changes and lightning discharges. To reduce the risk of damage to devices connected to such lines, surge limiting circuits are used. The protection module has been developed for such applications. The built-in two-stage protection circuit suppresses most surges induced in cables to a level safe for connected devices.
Video protection parameters
Connectors: 8x Male BNC, 8x Female BNC 75OHM
Video surge protection: nominal: 5KA (In(8/20us), maximum: 10KA (Imax(8/20us), Up: 15V, Un=5V, Uc=10V
Insertion loss: 0.2dB
Vs=10Mbps (Data transmission rate)
Ta=1nS (corresponsive time)
Operating temperature: -25 - +65 deg
Humidity: 95%
Standard: IEC61643-21: 2000
Grounding: YES (required)
Arrester dimensions, weight
Cable length: 40cm
Dimensions: wy11mm
Weight: waga11g
Application: Industrial television systems, satellite and cable television, broadcasting stations, traffic video stations, Terrestrial television
CE, RoHS
Arrester parameters
12 months
Certificates and standards
Arrester
Packaging
Manual
Warranty
Dimensions, Weight
Product dimensions: 0 x 0 x 0 mm (Depth x Width x Height)
Packaging dimensions: 200 x 200 x 70 mm (Depth x Width x Height)
Product weight: 500 g
Weight with packaging: 647 g
Specific References