- New
The second pillar of safety is the photoelectric smoke detector. Its task is to detect a fire in its earliest phase, when smoke begins to smolder and flames are not yet visible. The photoelectric sensor is much more resistant to false alarms caused by, for example, water vapor than older types of sensors. When a threat is detected, both devices emit a very loud sound signal with an intensity of over 85 decibels, which will effectively wake up the household members. The set is completely wireless and battery-powered (AA and 9V batteries are included), which ensures continuity of protection even during power outages. The aesthetic, white housing with compact dimensions makes the devices discreetly blend into any interior. Compliance with strict European standards EN 50291-1 and EN 14604, confirmed by independent certification bodies (TUV, BSI), ensures the highest reliability. Simple installation using the included wall plugs and intuitive one-button operation make the Virone DC-7 set the best choice for those who value safety and comfort.
EAN: 6931240044728 SKU: 931044722
The Virone DC-7 set is a professional safety package consisting of two high-class detectors: a carbon monoxide (CO) sensor and a smoke sensor. It is an ideal solution for every household, providing protection against the two most serious fire and gas threats. Carbon monoxide is an insidious gas – it has no smell, taste, or color, making it undetectable to human senses. The CO detector included in the DC-7 set uses an advanced electrochemical sensor that guarantees precise measurement even of small CO concentrations. The device has a clear, backlit LCD display that not only shows the current carbon monoxide level in PPM units but also acts as a home weather station, displaying temperature and air humidity. This allows the user to maintain optimal conditions in the bedroom or living room. The sensor lifespan is up to 10 years, making it a long-term investment.
The second pillar of safety is the photoelectric smoke detector. Its task is to detect a fire in its earliest phase, when smoke begins to smolder and flames are not yet visible. The photoelectric sensor is much more resistant to false alarms caused by, for example, water vapor than older types of sensors. When a threat is detected, both devices emit a very loud sound signal with an intensity of over 85 decibels, which will effectively wake up the household members. The set is completely wireless and battery-powered (AA and 9V batteries are included), which ensures continuity of protection even during power outages. The aesthetic, white housing with compact dimensions makes the devices discreetly blend into any interior. Compliance with strict European standards EN 50291-1 and EN 14604, confirmed by independent certification bodies (TUV, BSI), ensures the highest reliability. Simple installation using the included wall plugs and intuitive one-button operation make the Virone DC-7 set the best choice for those who value safety and comfort.
Device type
Set of autonomous safety sensors (Carbon Monoxide + Smoke)
CO sensor - Detection
Carbon monoxide (CO) via a precise Type B electrochemical sensor
CO sensor - Alarm thresholds
300 ppm (alarm within 3 min), 100 ppm (10-40 min), 50 ppm (60-90 min), 30 ppm (>120 min)
CO sensor - Display and functions
LCD with backlight, concentration measurement 25-999 ppm, built-in temperature and air humidity sensor
Smoke sensor - Detection
Visible smoke detected by an advanced photoelectric chamber
Alarm signaling
Acoustic (piezoelectric siren > 85 dB / 3 m) and optical (red LED)
CO sensor power supply
2 x 1.5V LR6 AA battery (included), power consumption 21µA (standby) / 3.6mA (alarm)
Smoke sensor power supply
1 x 9V 6F22/6LR61 battery (included), power consumption 10µA (standby) / 30mA (alarm)
Sensor lifespan
10 years from the date of activation for both detectors (CO and smoke)
Operating temperature
CO sensor: -10 °C ... 40 °C; Smoke sensor: -10 °C ... 50 °C
Standards and certificates
CO: PN-EN 50291-1:2018-06+AC:2021-03 (TUV); Smoke: PN-EN 14604:2006+AC:2009 (BSI-KM514007)
Component dimensions
CO sensor: 126 x 77 x 34 mm; Smoke sensor: Ø 107 x 27 mm
Component weight
CO sensor: 0.18 kg; Smoke sensor: 0.12 kg
Diagnostic functions
Test/Mute button, fault signaling, low battery alarm, end-of-life indicator
Software and logic
The devices are equipped with advanced firmware responsible for real-time air sample analysis. The carbon monoxide sensor algorithm precisely calculates the cumulative CO dose, which allows for avoiding false alarms during short-term concentration spikes, while guaranteeing an immediate reaction to a real threat. The smoke detector operating system uses advanced signal processing from the photoelectric chamber, compensating for the influence of dust and component aging, which significantly extends maintenance-free operation. The entire software has been optimized for ultra-low power consumption, which enables operation on a single set of batteries for a long time. The user is informed about the system status via error codes on the LCD display and sequences of sound signals, which facilitates quick diagnostics without the need for specialized tools.
Contents
1x Carbon monoxide (CO) detector Virone DC-6
1x Smoke detector Virone SD-1
2x 1.5V AA battery
1x 9V 6F22 battery
Set of mounting plugs
User manual in Polish
Dimensions, Weight
Product dimensions: 34 x 126 x 77 mm (D x W x H)
Packaging dimensions: 40 x 235 x 115 mm (D x W x H)
Product weight: 300 g
Weight with packaging: 394 g