Heating Circuit Temperature Sensor, Pool Water, Heat Pump Panasonic Aquarea PAW-A2W-TSBU 5m ACTii AC2305
The sensor is intended for all Panasonic heat pumps in which the acceptable sensor is marked: PAW-A2W-TSBU, (the user manual lists the sensor model intended for a given heat pump)
Sensor cable length: 5m
Buffer Tank Temperature Sensor, Heat Pump Panasonic Aquarea PAW-A2W-TSBU 5m
Model: ACTii AC2305
EAN: 6931240023051 SKU: 230521792
- High-quality, precise temperature sensor
- A specialized BiT LiYY 2x0.5mm copper flexible control cable was used, voltage: 300/300V, operating temperature: -40℃ to 80℃ compliant with the EU standard: LVD 2014/35/EU
- The sensor is placed in a sleeve with a diameter of 6 mm and a length of 50 mm, made of Stainless Steel.
- Each sensor is tested for 3 different temperatures to ensure that the measurements are consistent with the reference sensor.
- Our temperature sensors are better. Unlike the competition, we only use 100% thick copper, certified control cable produced in the EU with thick and flexible insulation. We use sensors from branded companies. We check each sensor for compliance of measurements with the reference sensor.
Description
Buffer tank temperature sensor, designed for Panasonic Aquarea heat pumps from the H series
The sensor is intended for all Panasonic heat pumps in which the acceptable sensor is marked: PAW-A2W-TSBU, (the user manual lists the sensor model intended for a given heat pump)
Sensor cable length: 5m
Specification
Sensor Parameters
Sensor compatible with Panasonic Aquarea
Purpose: Panasonic Heat Pumps
Sensor measurement range: -40 to +400 °C
Tightness: IP68
The sensor is placed in a sleeve with a diameter of 6 mm and a length of 50 mm, made of Stainless Steel.
Cable Termination: 2x Straight connector crimped on the cable
Cable length: 5m (196 inch)
Cable parameters
Cable parameters:
Cable type: Control/signaling cable
Operating voltage: 300/300V
Voltage test: ≤ 0.34mm2 1200 V, ≥ 0.5 mm2 1500 V
Insulation resistance: 20 MΩ x km
Capacitance: (at 800Hz): 0.14mm2 120pF/m, ≥0.25mm2 150pF/m
Inductance: 0.65mH/km
Min. bending radius of movable joints: 7.5 x Ø
Min. bending radius of permanent connection: 4 x Ø
Operating temperature: Permanent installation: -40℃ to 80℃, Mobile installations: -5℃ to 80℃
Laying conditions: Indoor cable, Min. laying temperature: -5℃
Environmental resistance: No flame spread on a single cable
Certificates / Approvals / Approvals: CPR - Certificates / DoP
Cable construction:
Core material: copper wires
Construction of working conductors: Class 5 (according to EN 60228, IEC 60228)
Center structure: multi-core cable
Application: Cables intended for control and signaling circuits in industrial applications, in measurement technology and for data transmission via analog and digital signals in industrial electronics and automation installations. For permanent installation and for mobile devices. They are suitable for use in indoor installations, in dry and humid rooms.
Other information
Our offer includes temperature sensors with different cable lengths
Purpose of the temperature sensor
Designed for Panasonic Aquarea heat pumps from the H series
Buffer Temperature Sensor, Buffer Tank (PAW-A2W-TSBU)
Set contents
Temperature sensor with a 5m cable
Certificates and standards
CE,RoHS
Dimensions, Weight
Product dimensions: 50 x 50 x 250 mm (D x W x H)
Dimensions Packaging: 50 x 50 x 250 mm (D x W x H)
Product weight: 270 g
Weight with packaging: 280 g
To download
Specific References
- EAN13
- 6931240023051