Liquid Water Level Sensor Relay Probe Pump Protection Drainage Filling Draining Tank 230W ACTii AC5462
search
  • Liquid Water Level Sensor Relay Probe Pump Protection Drainage Filling Draining Tank 230W ACTii AC5462
  • Liquid Water Level Sensor Relay Probe Pump Protection Drainage Filling Draining Tank 230W ACTii AC5462
  • Liquid Water Level Sensor Relay Probe Pump Protection Drainage Filling Draining Tank 230W ACTii AC5462
  • Liquid Water Level Sensor Relay Probe Pump Protection Drainage Filling Draining Tank 230W ACTii AC5462
  • Liquid Water Level Sensor Relay Probe Pump Protection Drainage Filling Draining Tank 230W ACTii AC5462
  • Liquid Water Level Sensor Relay Probe Pump Protection Drainage Filling Draining Tank 230W ACTii AC5462
  • Liquid Water Level Sensor Relay Probe Pump Protection Drainage Filling Draining Tank 230W ACTii AC5462

Liquid Water Level Sensor Relay Probe Pump Protection Drainage Filling Draining Tank 230W ACTii AC5462

zł99.21
Delivery within 3-4 days.
Water level sensor with a relay powered directly from the 230V network.

The device is used to protect the pump against dry running, to drain drainage, to protect against overfilling of the tank, to control the water level in one or two tanks.

Four working modes:

1.Filling the tank. Tank overfill protection. The water level reaches the upper probe - the pump stops pumping water into the tank. The water level drops below the lower probe - the pump is turned on (refilling the tank).

2. Emptying the tank. Protection against emptying the tank, e.g. emptying the drain (protection of the pump against dry running). The water level reaches the upper probe - the pump turns on. The water level drops to the lower probe - the pump turns off.

3. Emptying the tank. Protection against emptying the tank. Immediate pump shutdown when the water level reaches the lower probe.

4. Filling the upper tank from the lower tank. Protection against overfilling of the upper tank and protection against emptying the lower tank (including protection of the pump against dry running)

Quantity
Product available

Liquid Water Level Sensor Relay Probe Pump Protection Drainage Filling Draining Tank 230W

Model: ACTii AC5462

EAN: 6931240054628 SKU: 5462334234

  • Power supply directly from 230V mains, 10A relay
  • Solid workmanship
  • Four working modes
  • ON / OFF / AUTO switch. Allows for manual switching on and off of the pump and for automatic operation (according to probe readings)
  • LED operation signaling.

Description

Water level sensor with a relay powered directly from the 230V network.

The device is used to protect the pump against dry running, to drain drainage, to protect against overfilling of the tank, to control the water level in one or two tanks.

Four working modes:

1.Filling the tank. Tank overfill protection. The water level reaches the upper probe - the pump stops pumping water into the tank. The water level drops below the lower probe - the pump is turned on (refilling the tank).

2. Emptying the tank. Protection against emptying the tank, e.g. emptying the drain (protection of the pump against dry running). The water level reaches the upper probe - the pump turns on. The water level drops to the lower probe - the pump turns off.

3. Emptying the tank. Protection against emptying the tank. Immediate pump shutdown when the water level reaches the lower probe.

4. Filling the upper tank from the lower tank. Protection against overfilling of the upper tank and protection against emptying the lower tank (including protection of the pump against dry running)

Specification

Parameters

Power supply: 230V AC

Relay maximum switching power: 10A

Switch: ON / OFF / AUTO

Probe cable length: 2m

Maximum probe cable length: 300m

Probe supply voltage: 10V AC

Pump connection:

1. Direct control mode

Electrically operated single-phase power supply, power consumption does not exceed the rated capacity of the relay (resistive load 10A inductive load 5A), can be used for direct control mode

2. Single-phase expander mode

Electrically controlled single-phase power supply, power consumption does not exceed the rated capacity of the relay. Then a capacity in excess of the electrical power is needed for expansion of the exchange and contacts

3. Three-phase operation mode

Three-phase power supply is electrically controlled, requires an external three-phase line contactor.

Grey colour

Kit contents

Sensor

3x Probe

Certificates and standards

CE, RoHS

Dimensions, Weight

Product dimensions: 126 x 88 x 51 mm (D x W x H)

Packaging dimensions: 130 x 90 x 60 mm (D x W x H)

Product weight: 300 g

Weight with packaging: 350 g

To download

  • User manual
  • Instruction PL 1
  • DE instruction
  • Instruction EN
  • CE declaration of conformity
  • 5462334234
    26 Items

    Specific References

    EAN13
    6931240054628
    Comments (0)